modula S-TP
The Twin-Pass Reverse Osmosis System for highest water treatment quality demands and operational safety particularly for regions with pure water quality.Performance parameters
- Permeate capacity at 12°C water temperature: 350 l/h – 1750 l/h
- Water saving technology by consumption control
- 100% redundancy by twin-pass design of the RO system
- Manufactured according to MDD (Medical Device Directive)
Technical highlights
- Submersible pump in the break tank (free inlet) of the 1st stage and frequency controlled pump at the 2nd stage for minimized noise operation.
- Possibility of shifting between the 1st and 2nd stage
- Possibility of fault clearance respectively replacement of components during the operation
- Water saving technology by consumption control (conductivity controlled and temperature compensated)
- Programmable pre-flushing mode permeate to drain
- Internal surface of passivated stainless steel piping (chemical stained) with clamp connectors
- Energy saving polyamide membranes for maximum permeate yield at low pressure
- Possibility of emergency operation in case of breakdown of circuit board
- Monitoring of water consumption per hour
- Permeate pressure sustaining valves at permeate outlet and return
- Sampling and disinfection point permeate at 1st and 2nd stage
Weight: max. 500 kg
Further information: modula S-TP (pdf, 987 KB)